$ sudo smartctl -x /dev/sda
smartctl 6.2 2013-07-26 r3841 [i686-linux-3.12.6-200.fc19.i686.PAE] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Momentus 7200.4
Device Model:     ST9500420AS
Serial Number:    5VJ68AY2
LU WWN Device Id: 5 000c50 02a34d469
Firmware Version: 0002SDM1
User Capacity:    500,107,862,016 bytes [500 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    7200 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Fri Jan 17 07:49:52 2014 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is:     208 (intermediate), recommended: 208
APM level is:     128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, frozen [SEC2]
Wt Cache Reorder: Unknown

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      ( 121) The previous self-test completed having
                                        the read element of the test failed.
Total time to complete Offline 
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x73) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 107) minutes.
Conveyance self-test routine
recommended polling time:        (   3) minutes.
SCT capabilities:              (0x103f) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     POSR--   085   074   006    -    243348742
  3 Spin_Up_Time            PO----   100   100   085    -    0
  4 Start_Stop_Count        -O--CK   100   100   020    -    96
  5 Reallocated_Sector_Ct   PO--CK   100   100   036    -    0
  7 Seek_Error_Rate         POSR--   084   060   030    -    238612361
  9 Power_On_Hours          -O--CK   087   087   000    -    11535
 10 Spin_Retry_Count        PO--C-   100   100   097    -    0
 12 Power_Cycle_Count       -O--CK   100   100   020    -    96
184 End-to-End_Error        -O--CK   100   100   099    -    0
187 Reported_Uncorrect      -O--CK   001   001   000    -    3765
188 Command_Timeout         -O--CK   100   099   000    -    4295032839
189 High_Fly_Writes         -O-RCK   100   100   000    -    0
190 Airflow_Temperature_Cel -O---K   064   050   045    -    36 (Min/Max 33/43)
191 G-Sense_Error_Rate      -O--CK   100   100   000    -    6
192 Power-Off_Retract_Count -O--CK   100   100   000    -    51
193 Load_Cycle_Count        -O--CK   097   097   000    -    7794
194 Temperature_Celsius     -O---K   036   050   000    -    36 (0 21 0 0 0)
195 Hardware_ECC_Recovered  -O-RC-   046   044   000    -    243348742
197 Current_Pending_Sector  -O--C-   100   100   000    -    8
198 Offline_Uncorrectable   ----C-   100   100   000    -    8
199 UDMA_CRC_Error_Count    -OSRCK   200   200   000    -    0
240 Head_Flying_Hours       ------   100   253   000    -    132680129719553
241 Total_LBAs_Written      ------   100   253   000    -    2525013242
242 Total_LBAs_Read         ------   100   253   000    -    2162196433
254 Free_Fall_Sensor        -O--CK   100   100   000    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01       GPL,SL  R/O      1  Summary SMART error log
0x02       GPL,SL  R/O      5  Comprehensive SMART error log
0x03       GPL,SL  R/O      5  Ext. Comprehensive SMART error log
0x06       GPL,SL  R/O      1  SMART self-test log
0x07       GPL,SL  R/O      1  Extended self-test log
0x09       GPL,SL  R/W      1  Selective self-test log
0x10       GPL,SL  R/O      1  NCQ Command Error log
0x11       GPL,SL  R/O      1  SATA Phy Event Counters
0x21       GPL,SL  R/O      1  Write stream error log
0x22       GPL,SL  R/O      1  Read stream error log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xa1       GPL,SL  VS      20  Device vendor specific log
0xa2       GPL     VS    2248  Device vendor specific log
0xa8       GPL,SL  VS      65  Device vendor specific log
0xa9       GPL,SL  VS       1  Device vendor specific log
0xb0       GPL     VS    2864  Device vendor specific log
0xbe-0xbf  GPL     VS   65535  Device vendor specific log
0xe0       GPL,SL  R/W      1  SCT Command/Status
0xe1       GPL,SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 3761 (device log contains only the most recent 20 errors)
        CR     = Command Register
        FEATR  = Features Register
        COUNT  = Count (was: Sector Count) Register
        LBA_48 = Upper bytes of LBA High/Mid/Low Registers ]  ATA-8
        LH     = LBA High (was: Cylinder High) Register    ]   LBA
        LM     = LBA Mid (was: Cylinder Low) Register      ] Register
        LL     = LBA Low (was: Sector Number) Register     ]
        DV     = Device (was: Device/Head) Register
        DC     = Device Control Register
        ER     = Error register
        ST     = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 3761 [0] occurred at disk power-on lifetime: 11535 hours (480 days + 15 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 22 7e 00 3d 2c 00 00  Error: UNC at LBA = 0x227e003d2c = 148142832940

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  60 00 00 00 08 00 22 7e 00 3d 28 40 00     18:47:33.157  READ FPDMA QUEUED
  60 00 00 00 08 00 36 68 00 f4 18 40 00     18:47:33.157  READ FPDMA QUEUED
  60 00 00 00 10 00 36 68 00 f4 00 40 00     18:47:33.157  READ FPDMA QUEUED
  60 00 00 00 10 00 36 45 00 f4 f0 40 00     18:47:33.155  READ FPDMA QUEUED
  61 00 00 00 28 00 19 f0 00 c1 60 40 00     18:47:33.155  WRITE FPDMA QUEUED

Error 3760 [19] occurred at disk power-on lifetime: 11535 hours (480 days + 15 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 22 7e 00 3d 2f 00 00  Error: UNC at LBA = 0x227e003d2f = 148142832943

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  60 00 00 00 08 00 22 7e 00 3d 28 40 00     18:47:22.327  READ FPDMA QUEUED
  60 00 00 00 28 00 31 16 00 0b 88 40 00     18:47:21.602  READ FPDMA QUEUED
  60 00 00 00 08 00 27 3e 00 50 48 40 00     18:47:21.474  READ FPDMA QUEUED
  60 00 00 00 08 00 27 3e 00 50 40 40 00     18:47:21.466  READ FPDMA QUEUED
  60 00 00 00 08 00 27 48 00 50 08 40 00     18:47:21.012  READ FPDMA QUEUED

Error 3759 [18] occurred at disk power-on lifetime: 11535 hours (480 days + 15 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 22 7e 00 3d 2a 00 00  Error: UNC at LBA = 0x227e003d2a = 148142832938

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  60 00 00 00 08 00 22 7e 00 3d 28 40 00     18:38:24.892  READ FPDMA QUEUED
  27 00 00 00 00 00 00 00 00 00 00 e0 00     18:38:24.891  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  ec 00 00 00 00 00 00 00 00 00 00 a0 00     18:38:24.889  IDENTIFY DEVICE
  ef 00 03 00 46 00 00 00 00 00 00 a0 00     18:38:24.889  SET FEATURES [Set transfer mode]
  27 00 00 00 00 00 00 00 00 00 00 e0 00     18:38:24.889  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]

Error 3758 [17] occurred at disk power-on lifetime: 11535 hours (480 days + 15 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 22 7e 00 3d 2a 00 00  Error: UNC at LBA = 0x227e003d2a = 148142832938

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  60 00 00 00 08 00 22 7e 00 3d 28 40 00     18:38:22.141  READ FPDMA QUEUED
  ea 00 00 00 00 00 00 00 00 00 00 a0 00     18:38:21.363  FLUSH CACHE EXT
  61 00 00 00 08 00 34 dd 00 23 30 40 00     18:38:21.363  WRITE FPDMA QUEUED
  ea 00 00 00 00 00 00 00 00 00 00 a0 00     18:38:21.223  FLUSH CACHE EXT
  61 00 00 00 60 00 34 dc 00 23 d0 40 00     18:38:21.221  WRITE FPDMA QUEUED

Error 3757 [16] occurred at disk power-on lifetime: 11535 hours (480 days + 15 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 22 7e 00 3d 2a 00 00  Error: UNC at LBA = 0x227e003d2a = 148142832938

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  60 00 00 00 08 00 22 7e 00 3d 28 40 00     18:29:26.834  READ FPDMA QUEUED
  60 00 00 00 20 00 33 de 00 24 28 40 00     18:29:26.833  READ FPDMA QUEUED
  61 00 00 00 48 00 27 c6 00 96 00 40 00     18:29:26.833  WRITE FPDMA QUEUED
  61 00 00 00 40 00 28 b0 00 9e 00 40 00     18:29:26.832  WRITE FPDMA QUEUED
  61 00 00 01 00 00 28 04 00 a7 00 40 00     18:29:26.832  WRITE FPDMA QUEUED

Error 3756 [15] occurred at disk power-on lifetime: 11535 hours (480 days + 15 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 22 7e 00 3d 2a 00 00  Error: UNC at LBA = 0x227e003d2a = 148142832938

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  60 00 00 00 20 00 33 de 00 24 28 40 00     18:29:24.022  READ FPDMA QUEUED
  60 00 00 00 08 00 22 7e 00 3d 28 40 00     18:29:24.021  READ FPDMA QUEUED
  60 00 00 00 20 00 33 de 00 24 08 40 00     18:29:24.021  READ FPDMA QUEUED
  60 00 00 00 20 00 33 dd 00 24 e8 40 00     18:29:24.021  READ FPDMA QUEUED
  60 00 00 00 20 00 33 dd 00 24 c8 40 00     18:29:24.020  READ FPDMA QUEUED

Error 3755 [14] occurred at disk power-on lifetime: 11534 hours (480 days + 14 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 22 7e 00 3d 27 00 00  Error: UNC at LBA = 0x227e003d27 = 148142832935

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  60 00 00 00 08 00 37 b6 00 1f 28 40 00     18:20:24.838  READ FPDMA QUEUED
  60 00 00 00 68 00 37 b5 00 1f b8 40 00     18:20:24.837  READ FPDMA QUEUED
  60 00 00 00 08 00 22 7e 00 3d 20 40 00     18:20:24.834  READ FPDMA QUEUED
  27 00 00 00 00 00 00 00 00 00 00 e0 00     18:20:24.833  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  ec 00 00 00 00 00 00 00 00 00 00 a0 00     18:20:24.810  IDENTIFY DEVICE

Error 3754 [13] occurred at disk power-on lifetime: 11534 hours (480 days + 14 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 22 7e 00 3d 27 00 00  Error: UNC at LBA = 0x227e003d27 = 148142832935

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  60 00 00 00 08 00 22 7e 00 3d 20 40 00     18:20:22.088  READ FPDMA QUEUED
  60 00 00 00 08 00 27 4b 00 50 08 40 00     18:20:20.964  READ FPDMA QUEUED
  60 00 00 00 08 00 27 4b 00 50 00 40 00     18:20:20.956  READ FPDMA QUEUED
  60 00 00 00 08 00 27 49 00 50 38 40 00     18:20:20.948  READ FPDMA QUEUED
  60 00 00 00 20 00 26 5f 00 8f 88 40 00     18:20:17.473  READ FPDMA QUEUED

SMART Extended Self-test Log Version: 1 (1 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed: read failure       90%     11528         574443398
# 2  Extended offline    Completed: read failure       90%     11528         574443398
# 3  Extended offline    Completed: read failure       90%     11528         574443398
# 4  Short offline       Completed: read failure       90%     11528         574443398
# 5  Short offline       Aborted by host               90%     11526         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  3
SCT Version (vendor specific):       522 (0x020a)
SCT Support Level:                   1
Device State:                        Active (0)
Current Temperature:                    36 Celsius
Power Cycle Min/Max Temperature:     33/43 Celsius
Lifetime    Min/Max Temperature:     21/50 Celsius
Lifetime    Average Temperature:        39 Celsius
Under/Over Temperature Limit Count:   0/0
SCT Temperature History Version:     2
Temperature Sampling Period:         1 minute
Temperature Logging Interval:        1 minute
Min/Max recommended Temperature:     14/55 Celsius
Min/Max Temperature Limit:           10/60 Celsius
Temperature History Size (Index):    128 (87)

Index    Estimated Time   Temperature Celsius
  88    2014-01-17 05:42    37  ******************
 ...    ..(  6 skipped).    ..  ******************
  95    2014-01-17 05:49    37  ******************
  96    2014-01-17 05:50    36  *****************
  97    2014-01-17 05:51    37  ******************
  98    2014-01-17 05:52    36  *****************
  99    2014-01-17 05:53    36  *****************
 100    2014-01-17 05:54    36  *****************
 101    2014-01-17 05:55    37  ******************
 ...    ..(  5 skipped).    ..  ******************
 107    2014-01-17 06:01    37  ******************
 108    2014-01-17 06:02    36  *****************
 109    2014-01-17 06:03    37  ******************
 ...    ..( 12 skipped).    ..  ******************
 122    2014-01-17 06:16    37  ******************
 123    2014-01-17 06:17    36  *****************
 ...    ..( 28 skipped).    ..  *****************
  24    2014-01-17 06:46    36  *****************
  25    2014-01-17 06:47    37  ******************
 ...    ..( 30 skipped).    ..  ******************
  56    2014-01-17 07:18    37  ******************
  57    2014-01-17 07:19    36  *****************
 ...    ..( 20 skipped).    ..  *****************
  78    2014-01-17 07:40    36  *****************
  79    2014-01-17 07:41    35  ****************
  80    2014-01-17 07:42    36  *****************
  81    2014-01-17 07:43    36  *****************
  82    2014-01-17 07:44    35  ****************
  83    2014-01-17 07:45    36  *****************
 ...    ..(  3 skipped).    ..  *****************
  87    2014-01-17 07:49    36  *****************

SCT Error Recovery Control:
           Read: Disabled
          Write: Disabled

Device Statistics (GP Log 0x04) not supported

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x000a  2            2  Device-to-host register FISes sent due to a COMRESET
0x0001  2            0  Command failed due to ICRC error
0x0003  2            0  R_ERR response for device-to-host data FIS
0x0004  2            0  R_ERR response for host-to-device data FIS
0x0006  2            0  R_ERR response for device-to-host non-data FIS
0x0007  2            0  R_ERR response for host-to-device non-data FIS